中国能源研究会品牌分会 指导Guided by ICC China
公 告NOTICE更多 ›More ›
首页Home>资讯详情Item Detail>绿氢装备的缺陷清单:一次验收测试事故与电堆的衰减路径

绿氢装备的缺陷清单:一次验收测试事故与电堆的衰减路径Defect List of Green Hydrogen Equipment: An Acceptance Test Accident and the Degradation Path of the Stack

资讯详情Item Detail绿氢与氢基燃料 | 2026-10-28
信息来源:Source:中国能源产业发展网China Energy Industry Development Network
绿氢装备的缺陷清单:一次验收测试事故与电堆的衰减路径

行业里关于绿氢装备缺陷的讨论,通常止于一句寿命有待提升,真正能帮助工程判断的细节反而难得一见。2026年10月19日,一份来自英国上市公司的调查进展公告提供了少见的技术细节:Clean Power Hydrogen plc披露,其1兆瓦无膜电解槽MFFE220在2026年5月28日工厂验收测试第三阶段发生系统点火故障,设备遭受严重损坏。公告列出的调查结论很有价值,它没有把责任推给“技术路线本身”,也没有给出一个简单的答案,而是把多个可能因素并列出来,逐项说明各自的物理机制。这份公告连同近两年学界对质子交换膜电解槽衰减机理的持续研究,构成了当前绿氢装备缺陷图谱中最具工程价值的两块拼图。

工厂验收测试阶段的事故:为什么这一环节风险最高

先把事故过程说清楚。据公告,公司已完成针对2026年5月28日第三阶段暨最终阶段工厂验收测试期间事故的内部技术调查,虽然部分技术细节仍在由专业领域外部专家核实,董事会认为调查进展已足以提供更新。调查结论是:截至目前识别出若干个彼此无关的因素,这些因素很可能共同促成了事故,尚未确定单一的确定性点火源,且未发现任何证据表明事故起源于公司专有的无膜电堆或配套的分离器容器。列出的主要因素有四项:一是阀门V705附近的气体流速与颗粒冲击,可能在标准的受控排放过程中产生了足以引发点火的能量;二是部分止回阀、软管与管道弯头的规格与配置存在偏差;三是供应商质量以及露天测试设施的环境特点,对装置整体所需的“洁净度”造成了影响,导致机组内部出现颗粒物污染;四是这项新型技术设计与欧洲工业气体协会相关指导规范的“适用性与遵循程度”,目前正在作为补救设计流程的一部分予以评估。董事会认为这些主要因素组合在一起极有可能是测试失败的成因。

把这四项并排读,会发现事故的技术逻辑比一个单点失效复杂得多。事故发生在受控排放环节而不是正常运行环节,这一点尤其值得注意——受控排放本身是被当作安全程序来设计的常规动作,而恰恰是在这个动作里,系统需要把设备内部的气体安全地排出。如果点燃发生在正常运行阶段,问题多半出在电化学或主流程上;发生在排放环节,说明触发条件来自管路末端的流动细节与颗粒物的随机撞击。颗粒物污染之所以能成为一项独立因素,是因为它同时具备两个性质:一是它无处不在,供应商来料、装配过程、露天存放的测试场地都会引入;二是它的能量释放依赖于撞击速度,气体流速越高,颗粒撞击所携带的动能越大,理论上越可能提供点火所需的能量。阀门附近的局部流速异常会进一步放大这一效应——同样的管径,同样的总流量,流速分布一旦被某个部件的安装角度或几何突变打乱,就会在局部形成远高于平均值的速度。

公司对此采取的补救动作同样具有工程指示意义。公告明确指出,调查结论表明要成功完成测试,需要对某些部件设计、系统洁净度规程、制造控制与运行工况监测作出改变,公司已就此启动补救研究与设计工作,并计划在测试结果令人满意且董事会批准调查最终结论的前提下,向相关许可方与潜在制造合作伙伴提供修订后的设计包。值得注意的是,公司尚未公布完成工厂验收测试的时间表。一个明确的技术判断是:验收测试阶段的缺陷暴露,其成本远低于交付后的现场爆炸,但纠正周期通常以年计。对制造商而言,这意味着技术路线的可信度建立速度,会被一个原本可以归结为外部原因的故障实质性拖慢。

事故之后:一次失败如何改变了制造模式

这次事故引发的连锁反应,比技术细节本身更能说明产业当前所处阶段。据公开报道,在事故发生后,该公司的业务战略出现重大转向,从内部制造模式转为以知识产权为核心的战略。2026年6月25日,公司公告与爱尔兰Lisheen H2 Energy Park Limited(Hidrigin)签署了有约束力的条款清单,涉及一笔75.05万英镑的有担保可转换贷款票据,该票据以满足若干条件并签署最终文件为前提。与此前宣布的转向轻资产技术开发与授权业务的战略相一致,完成电解槽制造已不再在该公司内部进行,因此一项范围更广的战略伙伴关系与制造及技术开发协议正与Hidrigin协商之中。在超额认购的融资完成后,双方同意不再推进该可转换贷款票据,公司已退还此前在原有MFE220销售合同下收到的74.05万英镑临时款项,未发行该可转换贷款票据且未授予相关担保,Hidrigin的技术许可正在扩展,协议已就扩展至在美国的自用权利达成一致。

这组动作的工程含义比商务含义更值得记录。一家技术公司把制造从自有资产转为授权与合资,意味着它承认了自身在工艺管控与洁净度管理上的能力存在短板,同时把风险转移给具备制造能力的合作方。对整个行业而言,这提示了一个常被低估的事实:电解槽的技术路线可行性,与制造体系能否稳定复现,是两个独立的判断。一个新架构在实验室里成立,不等于它在产线上能保持一致;而一家已经具备规模制造能力的企业,也可能因为缺少洁净度与检测体系而在验收环节暴露短板。厂家考核体系和第三方认证的价值,正在于把后一个问题前置到设计阶段解决。

电堆内部的缺陷路径:氢气渗透如何吃掉电堆寿命

从设备层回到电化学层,缺陷路径同样清晰。质子交换膜电解槽中,氢气从阴极向阳极的渗透被认为是关键衰减途径。2026年8月14日发表于《ACS Energy Letters》的一项研究给出了机理层面的确认:研究将阴极向阳极的氢气渗透识别为低负载量铱催化剂在高电流密度下稳定性不足的关键原因,温度程序还原实验证实二氧化铱在80摄氏度氢气环境中会被还原,凸显了二氧化铱基催化剂在氢气暴露下的脆弱性;为缓解这一效应,研究引入钯作为阳极添加剂,使其作为氢氧化氢氧化催化剂抑制二氧化铱的还原,并通过电感耦合等离子体原子发射光谱与原位X射线吸收光谱验证,在氧覆盖的钯表面存在且处于析氧反应电位时,80摄氏度氢气流动条件下的铱溶解被显著抑制。

渗透之所以难以根治,根源在于它与降本的方向直接冲突。膜厚是抑制渗透最有效的物理手段,然而为了降低欧姆损耗、追求更高能效,膜厚正在被持续减薄,氢分子通过浓度梯度与扩散作用穿透膜的能力随之显著增强。行业公开的技术分析引用康明斯与学术界的合作研究指出,在典型工业运行条件下“氢渗透通量”通常维持在0.1至0.5毫安每平方厘米等效电流密度的水平;这一数值看似微小,后果却是多维度的。渗透到阳极的氢气会在阳极催化剂表面被氧化形成混合电位,这一过程不产生氧气却消耗电能,直接拉低法拉第效率,在系统运行初期效率通常接近100%,而随着膜老化产生针孔或裂纹,效率可能降至95%以下。更关键的是氢气与氧气在催化剂表面反应生成过氧化氢及其自由基,这些活性物种是导致全氟磺酸主链断裂与磺酸基团脱落的元凶;这类化学降解通常比电化学降解更难通过反向电流等操作修复。

结构决定渗透:两篇2026年论文给出的量化结论

2026年发表在《ACS Electrochemistry》上的一篇研究把这条路径量化到了结构层面。该研究建立了一个考虑微结构的多组分反应输运框架,分别解析溶解相与气相的氢输运路径,并把电极架构与渗透驱动的安全及性能问题建立机理关联。结论有两点值得记住:一是可操作性由阴极催化层与阳极多孔传输层共同主导,前者决定生成氢中经渗透损失的比例,后者决定阳极侧逸出氢的比例;二是在所考察的设计窗口内,提高阴极催化层中铂碳含量可使渗透通量下降最多23%,而提高阳极多孔传输层的孔隙率可使阳极尾气中的氢中氧体积分数下降0.6个百分点。研究进一步把这些响应整合进阴极压力与电流密度的映射图,并叠加安全与效率阈值,定义了两项统一指标用于衡量操作窗口的规模与质量。

这些数字的分量在于它们把一个笼统的氢渗透问题转化成了可以设计的变量。阴极催化层的铂碳含量与阳极多孔传输层的孔隙率都不是不可动的既定参数,而是可以在材料配方与结构设计层面调节的工程变量。铂碳用量的增加会推高阴极成本,因此真实的工程决策是在渗透通量、贵金属用量与法拉第效率之间求一个三维平衡,而不是单纯追求最低的铱负载量。另一层约束来自安全侧:氢气与氧气的混合物在铂催化剂上反应是危险的,混合物在4%时即成为爆炸性范围,因此相关标准要求混合比例保持在2%以下;而温度升高与电流密度升高都会增加渗透,这意味着这两项工况参数必须被统一管理而不能各自独立优化。

缺陷清单的三条通用结论

把设备事故与电化学研究放在一起,可以提炼出三条对国内绿氢装备产业同样成立的结论。第一,缺陷的分布规律是越靠近系统末端越容易被忽视。阀门与管路弯头的规格配置、系统洁净度、排放环节的流动组织,这些看起来属于辅助系统的环节,在事故归因里却承担了主要角色,而电堆本体反倒被排除嫌疑——这不是电堆不重要,而是辅助系统的失效模式更复杂、更依赖具体装配。第二,验收测试阶段是暴露缺陷性价比最高的环节,事故发生在工厂而非现场,已经属于运气;把颗粒物洁净度、阀门选型与配置、排放工况的流动组织纳入设计阶段的强制检查项,比在产线末端做拦截更经济。第三,衰减路径往往与降本路径相互冲突,膜减薄推高渗透、渗透消耗电能并损伤催化剂膜层、催化剂减量又降低对氢暴露的耐受度,这条链条决定了单点优化的收益会被链条另一端的退化抵消,因此真正的工程突破只能来自同时闭环的系统设计,而非某个环节的参数纪录。对国内产业而言,这个判断的实际含义是:跟踪一条路线的实验室指标意义有限,更值得跟踪的是该路线在量产线上的一致性数据、故障统计与第三方认证进展,这三项数据才是判断技术路线能否走向规模化的真实依据。

本文参考资料来源于Clean Power Hydrogen plc公开公告、RenewablesNow与全球氢能网公开报道;ACS Electrochemistry、ACS Energy Letters公开发表研究论文及美国能源部科学技术信息办公室收录文献;公开技术讲演与行业技术分析公开资料。

Discussions in the industry about defects in green hydrogen equipment usually stop at the statement that the lifespan needs improvement, while the details that could truly help engineers make judgments are rare. On October 19, 2026, a progress announcement from a UK listed company provided some rare technical details: Clean Power Hydrogen plc disclosed that its 1 MW membrane-free electrolyzer MFFE220 experienced a system ignition failure during the third phase of factory acceptance testing on May 28, 2026, causing severe damage to the equipment. The conclusions listed in the announcement are very valuable; they do not attribute blame to 'the technology itself,' nor do they provide a simple answer. Instead, they list multiple possible factors side by side and explain the physical mechanism of each. This announcement, along with nearly two years of continuous academic research on the degradation mechanism of proton exchange membrane electrolyzers, forms the two most engineering-valuable pieces of the current defect map for green hydrogen equipment.

Accidents during the factory acceptance testing phase: Why this stage carries the highest risk

First, clarify the sequence of the accident. According to the announcement, the company has completed an internal technical investigation of the accident that occurred during the third and final phase of the factory acceptance test on May 28, 2026. Although some technical details are still being verified by external experts outside the field, the Board believes that the progress of the investigation is sufficient to provide an update. The investigation concluded that, so far, several unrelated factors have been identified, which likely collectively contributed to the accident. No single definitive ignition source has been determined, and no evidence has been found to suggest that the accident originated from the company's proprietary membrane-free stacks or supporting separator containers. The four main factors listed are: first, the gas flow velocity and particle impact near valve V705, which could generate enough energy to trigger ignition during a standard controlled venting process; second, deviations in the specifications and configuration of certain check valves, hoses, and pipe elbows.

Third, the quality of suppliers and the environmental characteristics of the outdoor testing facilities have affected the 'cleanliness' required for the overall system, leading to particulate contamination inside the unit; fourth, the applicability and compliance of this new technology design with the relevant guidelines of the European Industrial Gases Association are currently being evaluated as part of the remedial design process. The board believes that the combination of these main factors is highly likely to be the cause of the test failure.

Reading these four items side by side, one finds that the technical logic of the accident is much more complex than a single-point failure. It is particularly noteworthy that the accident occurred during the controlled discharge phase rather than during normal operation—controlled discharge itself is a routine action designed as a safety procedure, and it is precisely during this action that the system needs to safely release gases from within the equipment. If ignition occurs during normal operation, the problem mostly lies in electrochemical aspects or the main process; if it occurs during the discharge phase, it indicates that the triggering conditions come from the flow details at the end of the pipeline and the random impact of particles. Particulate contamination can become an independent factor because it has two characteristics: first, it is ubiquitous, introduced through supplier materials, assembly processes, and outdoor testing sites; second, its energy release depends on impact speed—the higher the gas flow speed, the greater the kinetic energy carried by particle impacts, and theoretically, the more likely the energy required for ignition will be provided.

Local flow velocity anomalies near the valve can further amplify this effect—despite having the same pipe diameter and the same total flow rate, once the flow velocity distribution is disrupted by the installation angle or geometric changes of a particular component, it can create locally a speed far exceeding the average. The remedies the company has undertaken in response also carry engineering implications. The announcement clearly states that the investigation concluded that in order to successfully complete the tests, changes need to be made to the design of certain components, system cleanliness procedures, manufacturing controls, and operational condition monitoring. The company has already initiated remedial research and design work in this regard and plans, based on satisfactory test results and the board’s approval of the final investigation conclusions, to provide the revised design packages to relevant licensors and potential manufacturing partners. It is worth noting that the company has not yet announced a schedule for completing factory acceptance testing. A clear technical judgment is that the cost of exposing defects during the acceptance testing phase is far lower than that of on-site explosions after delivery, but the correction cycle usually spans years. For manufacturers, this means that the speed of establishing the credibility of a technical approach can be substantially slowed by a failure that could otherwise have been attributed to external factors.

After the accident: How a failure changed the manufacturing model

The chain reaction triggered by this accident illustrates the current stage of the industry more than the technical details themselves. According to public reports, after the accident, the company's business strategy underwent a major shift, moving from an internal manufacturing model to a strategy centered on intellectual property. On June 25, 2026, the company announced that it had signed a binding term sheet with Ireland's Lisheen H2 Energy Park Limited (Hidrigin), involving a secured convertible loan note of £750,500, conditional upon meeting certain conditions and signing the final documents. Consistent with the previously announced strategy of shifting to asset-light technology development and licensing business, the completion of electrolyzer manufacturing would no longer be carried out internally by the company; therefore, a broader strategic partnership and manufacturing and technology development agreement is currently under negotiation with Hidrigin.

After the financing was oversubscribed and completed, both parties agreed not to proceed with the convertible loan notes. The company has refunded the previous interim payment of £740,500 received under the original MFE220 sales contract. The convertible loan notes were not issued, and no related guarantees were granted. Hidrigin's technology license is being expanded, and the agreement has reached a consensus on extending the rights for self-use in the United States.

The engineering implications of this set of actions are more noteworthy than the business implications. When a tech company shifts manufacturing from its own assets to licensing and joint ventures, it indicates that the company acknowledges shortcomings in its process control and cleanliness management capabilities, while transferring the risks to partners who have manufacturing capabilities. For the entire industry, this points to a commonly underestimated fact: the feasibility of an electrolyzer technical route and the ability of the manufacturing system to reproduce it reliably are two independent assessments. A new architecture that works in the laboratory does not mean it can maintain consistency on the production line; likewise, a company that already has large-scale manufacturing capabilities may still reveal weaknesses during acceptance due to a lack of cleanliness and testing systems. The value of manufacturer assessment systems and third-party certification lies in addressing the latter issue at the design stage.

Defect paths inside the stack: how hydrogen permeation eats into the stack's lifespan.

Returning from the device layer to the electrochemical layer, the defect pathways are equally clear. In proton exchange membrane electrolyzers, hydrogen permeation from the cathode to the anode is considered a key degradation pathway. A study published on August 14, 2026, in ACS Energy Letters provided mechanistic confirmation: the study identified hydrogen permeation from the cathode to the anode as the critical reason for the insufficient stability of low-loaded iridium catalysts at high current densities. Temperature-programmed reduction experiments confirmed that iridium dioxide is reduced in an 80°C hydrogen environment, highlighting the vulnerability of iridium dioxide-based catalysts when exposed to hydrogen. To mitigate this effect, the study introduced palladium as an anode additive, enabling it to act as a hydrogen oxidation catalyst to suppress the reduction of iridium dioxide. Verification via inductively coupled plasma atomic emission spectroscopy and in situ X-ray absorption spectroscopy showed that under conditions of oxygen-covered palladium surfaces and at the oxygen evolution reaction potential, iridium dissolution is significantly suppressed under 80°C hydrogen flow.

The reason why permeation is difficult to eliminate lies in its direct conflict with cost reduction. Membrane thickness is the most effective physical means to inhibit permeation; however, in order to reduce ohmic loss and pursue higher energy efficiency, the membrane is continuously being thinned, which significantly enhances the ability of hydrogen molecules to penetrate the membrane through concentration gradients and diffusion. Publicly available industry technical analyses, citing collaborative research between Cummins and the academic community, indicate that under typical industrial operating conditions, the "hydrogen permeation flux" usually remains at a level equivalent to 0.1 to 0.5 mA per square centimeter in current density; although this number seems small, the consequences are multi-dimensional. Hydrogen that permeates to the anode is oxidized on the anode catalyst surface to form a mixed potential; this process does not produce oxygen but consumes electricity, directly lowering Faraday efficiency. While efficiency is usually close to 100% in the early stages of system operation, as the membrane ages and develops pinholes or cracks, efficiency may drop below 95%.

More importantly, hydrogen and oxygen react on the catalyst surface to produce hydrogen peroxide and its radicals, and these active species are the culprits causing the cleavage of the perfluorinated sulfonic acid main chain and the detachment of sulfonic groups; this type of chemical degradation is usually more difficult to repair through reverse currents and other operations than electrochemical degradation. Structure determines permeability: quantitative conclusions provided by two 2026 papers.

A study published in ACS Electrochemistry in 2026 quantified this pathway at the structural level. The study established a multi-component reaction-transport framework that considers microstructure, separately analyzing the hydrogen transport pathways in the dissolved phase and the gas phase, and mechanistically linking electrode architecture with safety and performance issues driven by permeation. There are two key conclusions to remember: first, operability is jointly dominated by the cathode catalyst layer and the anode porous transport layer, with the former determining the proportion of hydrogen lost through permeation during generation, and the latter determining the proportion of hydrogen escaping on the anode side; second, within the considered design window, increasing the platinum-carbon content in the cathode catalyst layer can reduce the permeation flux by up to 23%, while increasing the porosity of the anode porous transport layer can reduce the oxygen volume fraction in the hydrogen at the anode tail gas by 0.6 percentage points. The study further integrates these responses into a mapping of cathode pressure versus current density, overlaying safety and efficiency thresholds, and defines two unified indicators to measure the scale and quality of the operational window.

The significance of these numbers lies in their ability to transform a vague issue of hydrogen permeation into variables that can be designed. The platinum-carbon content in the cathode catalyst layer and the porosity of the anode porous transport layer are not fixed parameters; they are engineering variables that can be adjusted at the level of material formulation and structural design. Increasing the amount of platinum-carbon raises the cost of the cathode, so the real engineering decision is to find a three-dimensional balance among permeation flux, precious metal usage, and Faradaic efficiency, rather than merely aiming for the lowest iridium loading. Another layer of constraint comes from safety: the reaction of hydrogen-oxygen mixtures on a platinum catalyst is dangerous, and the mixture becomes explosive at 4%, so relevant standards require that the mixture ratio be kept below 2%. Both increased temperature and higher current density will increase permeation, which means these two operating parameters must be managed together and cannot be independently optimized.

Three general conclusions from the defect list

Placing equipment accidents together with electrochemical research allows us to extract three conclusions that also apply to the domestic green hydrogen equipment industry. First, the distribution pattern of defects is such that the closer to the end of the system, the more likely they are to be overlooked. Specifications of valves and pipe elbows, system cleanliness, and the flow organization at emission points—these aspects, which seem to be part of auxiliary systems, actually play a major role in accident attribution, while the stack itself is often ruled out as a suspect—not because the stack is unimportant, but because the failure modes of auxiliary systems are more complex and more dependent on specific assembly. Second, the acceptance testing phase is the most cost-effective stage to expose defects; if an accident occurs at the factory rather than on site, it is mostly a matter of luck. Incorporating particulate cleanliness, valve selection and configuration, and the flow organization under emission conditions into mandatory design-stage checks is more economical than attempting interception at the end of the production line.

Third, the degradation path often conflicts with the cost-reduction path. Thinning the membrane increases permeability, permeability consumes electrical energy and damages the catalyst layer, and reducing the amount of catalyst decreases tolerance to hydrogen exposure. This chain means that the gains from optimizing a single point will be offset by degradation at the other end of the chain. Therefore, real engineering breakthroughs can only come from a simultaneously closed-loop system design, rather than record-setting parameters in a single component. For the domestic industry, the practical implication of this judgment is: tracking laboratory indicators along one route is of limited significance; what is more worth tracking are the consistency data on the mass production line, failure statistics, and progress in third-party certification. These three sets of data are the true basis for determining whether a technology route can scale.

The references of this article are sourced from public announcements of Clean Power Hydrogen plc, public reports from RenewablesNow and Global Hydrogen Network; research papers published in ACS Electrochemistry and ACS Energy Letters, as well as documents indexed by the U.S. Department of Energy's Office of Scientific and Technical Information; publicly available technical lectures and industry technical analysis materials.

版权声明Copyright Notice

本网站摘录或转载的属于第三方的信息,目的在于传递更多信息,内容仅供参考。相关股票、投融资等资讯及分析并不代表本网站赞同其意见和对其真实性负责,不构成投资建议。

若不慎涉及侵权,请在相关内容刊发之日起 30 日内联系我们,我们将第一时间进行删除处理。

转载本网资讯请注明来源作者。本网原创文章、研究报告禁止转发。

Information excerpted or reprinted from third parties on this website is intended to convey more information for reference only. Related stocks, investment and financing news and analysis do not represent the endorsement of this website, nor does this website assume responsibility for their authenticity, and do not constitute investment advice.

If any content unintentionally infringes upon rights, please contact us within 30 days from the date of publication, and we will remove it as soon as possible.

When reprinting content from this website, please indicate the source and author. Original articles and research reports of this website may not be redistributed.

联系电话 / Tel010-85763416邮箱 / EmailEmail / Emaillsrlcyl_2026@163.com
提交留言留下联系方式,平台将把您的需求推送给匹配的产业方Leave your contact details and we will match you with relevant industry partners.
数据来源与免责声明Data Sources & Disclaimer

数据来源与口径说明:本平台数据与资讯均以「唯一官方口径」采集与发布,优先采用国家部委、国家统计局、海关总署、中国氢能联盟、IEA / IRENA / IMO 等官方或政府间机构公开数据;同一指标只取一个来源,不做多源拼接。数值为公开发布值,可能因统计口径、产地与发布时间不同而存在差异,仅供参考,不构成交易依据。Data sources and methodology: all data and news on this platform are collected and published from a single official source, giving priority to public data from government bodies and intergovernmental organisations such as the National Bureau of Statistics, the General Administration of Customs, the China Hydrogen Alliance, and IEA / IRENA / IMO. One indicator has one source only and is never stitched together from multiple sources. Figures are published values and may vary with statistical scope, origin and release date. For reference only; not a basis for transactions.

AI
智能客服Smart Assistant绿色燃料国际商务网 · 在线服务Green Fuel International Business Network · Online Service
×
人工服务:工作日 09:00—18:00 | 联系电话 010-85763416Human service: Weekdays 09:00—18:00 | Tel 010-85763416
智能客服Smart Assistant